17
Assembly Procedure 1450 Tower - 3T
Place xed platform initially at 3m level and
slide across to opposite side of tower (as
shown) from where operative is standing
below then place trapdoor platform
ensuring that trap is placed at same side to
trap on platform below.
Note Ensure that the trapdoor hinge is to the
outside edge.
14.
Odd Height Towers
Repeat step 9 and climb through the trap.
Fit horizontal braces to both sides of
platform at 1st and 2nd rungs above
platform level to form permanent
handrail.
It is safe to use the platform once
horizontal braces are locked and secured
in place.
15.
16.
Repeat steps 11 to 16 until desired height has been reached (max. height
8m outdoors and 12 m indoors).
DISMANTLING THE TOWER
At top platform level unlock horizontal
braces at furthest positions from the
trap before descending through the
trap.
As before, sit through the trap and rest
against the platform (just below base
of back) with feet rmly placed on
ladder rungs.
Remove horizontal braces and pass
down to operatives below.